IDSSE OpenIR  > 个人在本单位外知识产出
Direct pH measurement of NaCl-bearing fluid with in-situ sensor at 400°C and 40 MPa: Experimental results and theoretical predictions
Ding K.; Seyfried W.E. Jr.
1996-07-14
Source PublicationScience
Volume272Issue:5268Pages:1634-1636
DOI10.1126/science.272.5268.1634
Indexed BySCI
Citation statistics
Cited Times:53[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Version出版稿
Identifierhttp://ir.idsse.ac.cn/handle/183446/2633
Collection个人在本单位外知识产出
Corresponding AuthorDing K.
AffiliationDepartment of Geology and Geophysics, University of Minnesota, Minneapolis, MN 55455, USA.
Recommended Citation
GB/T 7714
Ding K.,Seyfried W.E. Jr.. Direct pH measurement of NaCl-bearing fluid with in-situ sensor at 400°C and 40 MPa: Experimental results and theoretical predictions[J]. Science,1996,272(5268):1634-1636.
APA Ding K.,&Seyfried W.E. Jr..(1996).Direct pH measurement of NaCl-bearing fluid with in-situ sensor at 400°C and 40 MPa: Experimental results and theoretical predictions.Science,272(5268),1634-1636.
MLA Ding K.,et al."Direct pH measurement of NaCl-bearing fluid with in-situ sensor at 400°C and 40 MPa: Experimental results and theoretical predictions".Science 272.5268(1996):1634-1636.
Files in This Item:
There are no files associated with this item.
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Ding K.]'s Articles
[Seyfried W.E. Jr.]'s Articles
Baidu academic
Similar articles in Baidu academic
[Ding K.]'s Articles
[Seyfried W.E. Jr.]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Ding K.]'s Articles
[Seyfried W.E. Jr.]'s Articles
Terms of Use
No data!
Social Bookmark/Share
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.